Cyclone-100 Cathodic Protection Coupon (100 cm² Cylindrical Steel)

The Cyclone-100 is a 100 cm² cylindrical “barrel” cathodic protection coupon in a durable PVC housing. Its larger surface area can give better coupon-to-soil contact on burial, and it ships with dual #12 AWG direct-burial leads in 25, 50, 75 or 100 foot lengths.
  • Cathodic protection coupons are a simple, size-specific piece of metal with one or more wires attached, used to evaluate the corrosion control or cathodic protection system protecting a structure — typically a steel pipeline.

    Measurements a Coupon Supports

    • Native or unprotected structure-to-soil potentials.
    • Structure-to-soil potentials with the CP system energised.
    • Structure-to-soil potentials with the CP system interrupted.
    • A “coupon interrupt” reading, emulating an “off” structure-to-soil potential without interrupting CP current.
    • Magnitude measurements of AC current density on a structure with known induced AC issues.

    The Cyclone-100 Design

    The Cyclone-100 steel CP coupon is a 100 cm² “barrel” or cylindrical coupon, a form common in CP testing. The larger surface area may provide better coupon-to-soil contact upon burial, which is an important consideration for testing.

    The coupon is mounted inside a durable PVC housing and is supplied with a dual length of #12 AWG stranded copper cable with RHH/RHW direct-burial insulation, typically green in colour.

    Choosing a Coupon Size

    Farwest cylindrical coupons are offered at 10 cm² (Cyclone-10) and 100 cm² (Cyclone-100). The larger area suits soils where reliable coupon-to-soil contact is difficult to achieve; the 10 cm² size is the convenient choice for AC current density, where milliamps convert directly to A/m².

  • Specifications

    Surface Area100 cm²
    ShapeCylindrical (“barrel”)
    MaterialSteel
    HousingDurable PVC
    CableDual length of #12 AWG stranded copper
    Cable InsulationRHH/RHW, rated for direct burial
    Cable Lengths25, 50, 75 or 100 feet
    Insulation ColourGreen standard; white, blue, orange and others available
    Key BenefitLarger surface area for improved coupon-to-soil contact on burial
    Typical UseCoupon potential and coupon interrupt readings
  • Coupon Ordering Information

    To order a Cyclone-100, confirm the following.

    • Specify the Cyclone-100 steel coupon.
    • Choose a cable length of 25, 50, 75 or 100 feet. A dual cable is supplied as standard.
    • Select a cable insulation colour. Green is the Farwest standard; white, blue, orange and others are available.

    Contact Farwest Corrosion at (310) 532-9524 or submit a quote request.

  • Frequently Asked Questions

    Why choose a 100 cm² coupon?

    The larger surface area may provide better coupon-to-soil contact upon burial, which matters where soil conditions make reliable contact hard to achieve.

    How does it compare to the Cyclone-10?

    Same cylindrical form and construction, ten times the surface area. The Cyclone-10 is the convenient size for AC current density because 10 cm² converts milliamps directly to A/m².

    Does it come with one lead or two?

    A dual length of #12 AWG stranded copper cable is supplied as standard.

    What cable lengths are available?

    25, 50, 75 or 100 feet, with RHH/RHW insulation rated for direct burial.

    What is a coupon interrupt reading?

    It emulates an “off” structure-to-soil potential without interrupting CP current to the structure.

    Can I get a cable colour other than green?

    Yes. Green is the Farwest standard; white, blue, orange and others are available.

    Is the coupon suitable for direct burial?

    Yes. The steel element sits in a durable PVC housing and the leads use direct-burial rated RHH/RHW insulation.

    Dimensional Drawing

    Cyclone-100 cathodic protection coupon drawing
Customers Who Viewed This Also Viewed
Model CI-50, 50 Amp Current Interrupter by Tinker & Rasor
PowerFill Electrical Grounding Backfill by Loresco
TC Profile Putty by Tapecoat
Stainless Steel Soil Pins by Farwest
Standard Coating Thickness Inspection, Kit #1 by Farwest