Flathead-10 Cathodic Protection Coupon (10 cm² Steel)

The Flathead-10 is a 10 cm² cathodic protection coupon in 1018 alloy steel, flush mounted in a durable PVC housing. The 10 cm² area converts milliamps directly to A/m² for AC current density work. Single or dual #12 AWG direct-burial leads in 25, 50, 75 or 100 foot lengths.
  • Cathodic protection coupons are a simple, size-specific piece of metal with one or more wires attached, used to evaluate the corrosion control or cathodic protection system protecting a structure — typically a steel pipeline.

    Measurements a Coupon Supports

    • Native or unprotected structure-to-soil potentials.
    • Structure-to-soil potentials with the CP system energised.
    • Structure-to-soil potentials with the CP system interrupted.
    • A “coupon interrupt” reading, emulating an “off” structure-to-soil potential without interrupting CP current.
    • Magnitude measurements of AC current density on a structure with known induced AC issues.
    • Use as an isolated coupon to evaluate native or unprotected potentials.

    The Flathead-10 Design

    The Flathead-10 steel coupon is a 10 cm² coupon made from 1018 alloy steel, flush mounted inside a durable PVC housing so the exposed surface area stays fixed and readings stay comparable over time.

    Each coupon includes a specified length of #12 AWG stranded copper cable with RHH/RHW direct-burial insulation, typically green in colour.

    Why 10 cm²

    A 10 cm² coupon makes better contact with native earth than a 1 cm² coupon, and for AC current density work the measured value converts directly from milliamps to A/m² with no arithmetic. A reading of 25.0 mA is 25 A/m².

    Where a flush-mounted profile is not required, the Hemi-10 offers a hemispherical shape for maximum earth contact and the Cyclone-10 a cylindrical one.

  • Specifications

    Surface Area10 cm²
    Material1018 alloy steel
    MountingFlush mounted in a durable PVC housing
    Cable#12 AWG stranded copper
    Cable InsulationRHH/RHW, rated for direct burial
    Lead OptionsSingle or dual cable lead
    Cable Lengths25, 50, 75 or 100 feet
    Insulation ColourGreen standard; white, blue, orange and others available
    Typical UseCoupon interrupt readings and AC current density measurement
    Conversion10 cm² converts mA directly to A/m²
  • Coupon Ordering Information

    To order a Flathead-10, confirm the following.

    • Specify the Flathead-10 steel coupon.
    • Select the number of cable lead wires, 1 or 2.
    • Choose a cable length of 25, 50, 75 or 100 feet.
    • Select a cable insulation colour. Green is the Farwest standard; white, blue, orange and others are available.

    Contact Farwest Corrosion at (310) 532-9524 or submit a quote request.

  • Frequently Asked Questions

    What size is the Flathead-10?

    10 cm² of exposed 1018 alloy steel. The Flathead-1 is the 1 cm² version of the same design.

    Why does 10 cm² matter for AC current density?

    At 10 cm² the measured milliamp value converts directly to amperes per square metre — 25.0 mA is 25 A/m² — so there is no conversion arithmetic in the field.

    Why is the coupon flush mounted?

    Flush mounting in the PVC housing fixes the exposed surface area, so the area behind every reading stays the same and results stay comparable.

    How does it differ from the Hemi-10 and Cyclone-10?

    All three are 10 cm² steel coupons. The Flathead-10 is flush mounted, the Hemi-10 is hemispherical for maximum earth contact, and the Cyclone-10 is cylindrical.

    What cable is supplied?

    #12 AWG stranded copper with RHH/RHW insulation rated for direct burial, in 25, 50, 75 or 100 foot lengths, as a single or dual lead.

    What is a coupon interrupt reading?

    It emulates an “off” structure-to-soil potential without interrupting CP current to the structure.

    Can I get a cable colour other than green?

    Yes. Green is the Farwest standard; white, blue, orange and others are available.

Customers Who Viewed This Also Viewed
Sleeves and Washers by Lamons
Zinc Anodes for Soil Application by Farwest Corrosion
Model N-10 Tester for Clamp-on DC Ammeters by Swain Meter
Test Lead Wires by Farwest Corrosion
Vapor Capsule Diffusers by Zerust