Hemi-10 Cathodic Protection Coupon (10 cm² Steel)
- The Hemi-10 is a 10 cm² hemispherical steel cathodic protection coupon in a durable PVC housing, shaped for maximum contact with native earth. Supplied with single or dual #12 AWG stranded copper leads in RHH/RHW direct-burial insulation, in 25, 50, 75 or 100 foot lengths.
-
Cathodic protection coupons are a simple, size-specific piece of metal with one or more wires attached, used to evaluate the corrosion control or cathodic protection system protecting a structure — typically a steel pipeline. A coupon lets the technician take readings that would otherwise require interrupting the CP system.
Measurements a Coupon Supports
- Native or unprotected structure-to-soil potentials.
- Structure-to-soil potentials with the CP system energised.
- Structure-to-soil potentials with the CP system interrupted.
- A “coupon interrupt” reading, emulating an “off” structure-to-soil potential without interrupting CP current.
- Magnitude measurements of AC current density on a structure with known induced AC issues.
The Hemi-10 Design
The Hemi-10 is a 10 cm² half-round steel CP coupon designed for maximum contact to earth, which is critically important for AC current density measurements.
The 10 cm² surface area gives better contact with native earth than a smaller 1 cm² coupon. For AC current density work it also allows a direct conversion from mA to A/m² with no mathematical conversion required.
The coupon is mounted inside a durable PVC housing and is supplied with a single or dual length of #12 AWG stranded copper cable with RHH/RHW direct-burial insulation, typically green in colour.
-
Specifications
Surface Area 10 cm² Shape Hemispherical (half-round), for maximum contact to native earth Material Steel Housing Durable PVC Cable #12 AWG stranded copper Cable Insulation RHH/RHW, rated for direct burial Lead Options Single or dual cable lead Cable Lengths 25, 50, 75 or 100 feet Insulation Colour Green standard; white, blue, orange and others available Typical Use Coupon interrupt readings and AC current density measurement The 10 cm² area converts directly from mA to A/m², which avoids the conversion arithmetic a 1 cm² coupon requires.
-
Coupon Ordering Information
To order a Hemi-10, confirm the following.
- Specify the Hemi-10 steel coupon.
- Select the number of cable lead wires, 1 or 2.
- Choose a cable length of 25, 50, 75 or 100 feet.
- Select a cable insulation colour. Green is the Farwest standard; white, blue, orange and others are available.
Contact Farwest Corrosion at (310) 532-9524 or submit a quote request to configure your coupons.
-
Frequently Asked Questions
Why choose a 10 cm² coupon over a 1 cm² coupon?
A 10 cm² coupon makes better contact with native earth, and for AC current density work the measured value converts directly from mA to A/m² with no arithmetic.
What makes the hemispherical shape useful?
The half-round profile maximises contact to earth, which matters most when measuring AC current density on a structure with known induced AC issues.
What is a coupon interrupt reading?
It emulates an “off” structure-to-soil potential without interrupting the CP current to the structure, so you get an instant-off style reading while the system stays energised.
What cable is supplied?
#12 AWG stranded copper with RHH/RHW insulation rated for direct burial, in 25, 50, 75 or 100 foot lengths, as a single or dual lead.
Can I get a cable colour other than green?
Yes. Green is the Farwest standard, and white, blue, orange and other colours are available — useful where several coupons share a test station.
Should I order one lead or two?
A dual lead allows the coupon to be connected and measured independently, which suits coupon interrupt and AC current density work where you want a dedicated measurement path.
Is the coupon suitable for direct burial?
Yes. The steel element sits in a durable PVC housing and the leads use direct-burial rated RHH/RHW insulation.