Rapid-Check Cathodic Protection Test Station

The Rapid-Check is a factory pre-wired cathodic protection test station that delivers the most-used CP readings from one dead-front enclosure — pipe-to-soil potentials, native and CP-on coupon potentials, coupon disconnect and AC current density. Quick-Connect terminal strip accepts up to #6 AWG, with a 0.1 ohm shunt, stationary reference electrode terminal and 3" x 6' standpipe included.
  • Cathodic protection test stations come in a wide variety of sizes, materials, shapes and colours. Typically an installed test station consists of one or more wires connected to a buried structure, such as a pipeline, routed above ground and terminated in an enclosure the CP technician can easily access. That gives the technician a direct connection to the pipeline, at a known location, for the measurements the survey requires.

    The Farwest Rapid-Check test station is designed to deliver the most-used CP readings from a single enclosure, to be user friendly and safe to operate, and to minimise installation cost.

    Why Specifiers Choose It

    • Factory pre-wired. Field wiring a new test station is slow and the details are often unclear to the installer. Every Rapid-Check assembly is pre-wired at the factory, so an incorrectly wired station is far less likely.
    • Quick-Connect terminal strip. A clearly labelled terminal block accepting up to #6 AWG cable is built into the assembly. Attach each wire to its specified position and the field wiring is complete.
    • Dead-front panel and rear shock guard. Prevents human contact with live wires and terminals.
    • AC/DC coupon terminal. Electrically connected to the pipeline terminal for measuring AC and DC pipe potentials, plus a coupon-disconnect reading via the momentary toggle switch that isolates the coupon from the pipeline.
    • Built-in 0.1 ohm shunt. Wired in line with the AC/DC coupon to measure AC current density. A direct AC current density reading can also be taken with a digital multimeter at the appropriate terminals.
    • RMU ready. The Rapid-Check interfaces with many popular Remote Monitoring Units, which can be installed adjacent to the unit for real-time field data.

    Note: 10 cm² coupons are preferred, as the measured value converts easily to amperes per square metre (A/m²).

  • Standard Components

    The Rapid-Check ships with the following components as standard, which together make installation straightforward.

    QtyComponent
    1Lexan test station body, 3" diameter
    2Pipeline connection terminals (black)
    1Stationary copper sulfate reference electrode terminal (yellow)
    1Native coupon terminal, isolated from all structures (white)
    1AC/DC coupon terminal (green) with momentary disconnect switch
    10.1 ohm shunt
    1Printed nameplate
    1“Dead” front panel with pre-wired banana jacks
    1Rear shock-guard safety cover
    13" x 6' long PE standpipe
    1Quick-Connect terminal strip with cable connection guide
    1Test station schematic drawing

    Key Specifications

    BodyLexan, 3" diameter
    Standpipe3" x 6' long polyethylene
    Terminal CapacityQuick-Connect terminal strip accepts up to #6 AWG cable
    Shunt0.1 ohm, wired in line with the AC/DC coupon
    Terminals2x pipeline (black), reference electrode (yellow), native coupon (white), AC/DC coupon (green)
    SwitchingMomentary disconnect switch on the AC/DC coupon terminal
    SafetyDead-front panel with pre-wired banana jacks; rear shock-guard cover
    WiringPre-wired at the factory; labelled terminal block with cable connection guide
    ColourSpecified at time of order
    RMU InterfaceCompatible with many popular Remote Monitoring Units
  • Applications

    The Rapid-Check is purposely built to allow specific CP test measurements, including but not limited to the following.

    Pipe-to-Soil Potentials

    Taken with a portable or stationary reference electrode, to test the effectiveness of the CP system and detect the presence of cathodic interference.

    Coupon Measurements

    • Native structure-to-soil potential.
    • CP “on” potential.
    • Coupon disconnect potential, emulating an instant CP-off potential.
    • AC current density for pipelines installed in AC power transmission corridors.

    Note: induced AC voltages and the associated AC currents can be both a personnel shock hazard and, in some cases, a threat to pipeline integrity from AC corrosion.

  • Ordering Information & Options

    When ordering a Rapid-Check test station, please confirm the following.

    • Test station colour. Specify the colour required.
    • Standard configuration. Confirm that the standard configuration meets the needs of your site.
    • Optional equipment. Coupons, a reference electrode, wiring and similar accessories can be supplied alongside the station.

    Remote Monitoring

    Many CP operators are installing Remote Monitoring Units to obtain real-time field data. The Rapid-Check interfaces with many popular RMU products, and the RMU can be installed adjacent to the Rapid-Check unit.

    Contact Farwest Corrosion at (310) 532-9524 or submit a quote request to configure a Rapid-Check for your application.

    Documentation

  • Frequently Asked Questions

    What readings can the Rapid-Check take?

    Pipe-to-soil potentials with a portable or stationary reference electrode, native structure-to-soil potential, CP “on” potential, coupon disconnect potential emulating an instant-off reading, and AC current density.

    Does it come pre-wired?

    Yes. Every assembly is pre-wired at the factory and fitted with a labelled Quick-Connect terminal block, so the installer attaches each field wire to its specified position and the wiring is complete.

    What size cable does the terminal strip accept?

    Up to #6 AWG.

    How is AC current density measured?

    A 0.1 ohm shunt is wired in line with the AC/DC coupon. A direct AC current density reading can also be taken by connecting a digital multimeter to the appropriate terminals. 10 cm² coupons are preferred because the measured value converts easily to A/m².

    How does the coupon disconnect reading work?

    The AC/DC coupon terminal is electrically connected to the pipeline terminal. A momentary toggle switch disconnects the coupon from the pipeline, giving a coupon disconnect potential that emulates an instant CP-off reading.

    Is it safe to work on in the field?

    The station uses a dead-front panel with pre-wired banana jacks and a rear shock-guard safety cover to prevent contact with live wires and terminals.

    Can it work with a remote monitoring unit?

    Yes. The Rapid-Check interfaces with many popular RMU products, and the RMU can be installed adjacent to the unit.

    What is included in the standpipe?

    A 3" x 6' long polyethylene standpipe is supplied as part of the standard assembly.

Customers Who Viewed This Also Viewed
Model FE Through Wall, Extreme Environment Reference Electrode by EDI
Bullhorn Model RM4014 & RM4015 Remote Monitors by American Innovations
Stelth 7 Stationary Reference Electrode, IR Free, by Borin Mfg.
170 Series Digital Multimeters by Fluke
Model MER Clamp-on Digital DC Ammeter with Magnetic Error Correction by Swain Meter