Rapid-Check Cathodic Protection Test Station
- The Rapid-Check is a factory pre-wired cathodic protection test station that delivers the most-used CP readings from one dead-front enclosure — pipe-to-soil potentials, native and CP-on coupon potentials, coupon disconnect and AC current density. Quick-Connect terminal strip accepts up to #6 AWG, with a 0.1 ohm shunt, stationary reference electrode terminal and 3" x 6' standpipe included.
-
Cathodic protection test stations come in a wide variety of sizes, materials, shapes and colours. Typically an installed test station consists of one or more wires connected to a buried structure, such as a pipeline, routed above ground and terminated in an enclosure the CP technician can easily access. That gives the technician a direct connection to the pipeline, at a known location, for the measurements the survey requires.
The Farwest Rapid-Check test station is designed to deliver the most-used CP readings from a single enclosure, to be user friendly and safe to operate, and to minimise installation cost.
Why Specifiers Choose It
- Factory pre-wired. Field wiring a new test station is slow and the details are often unclear to the installer. Every Rapid-Check assembly is pre-wired at the factory, so an incorrectly wired station is far less likely.
- Quick-Connect terminal strip. A clearly labelled terminal block accepting up to #6 AWG cable is built into the assembly. Attach each wire to its specified position and the field wiring is complete.
- Dead-front panel and rear shock guard. Prevents human contact with live wires and terminals.
- AC/DC coupon terminal. Electrically connected to the pipeline terminal for measuring AC and DC pipe potentials, plus a coupon-disconnect reading via the momentary toggle switch that isolates the coupon from the pipeline.
- Built-in 0.1 ohm shunt. Wired in line with the AC/DC coupon to measure AC current density. A direct AC current density reading can also be taken with a digital multimeter at the appropriate terminals.
- RMU ready. The Rapid-Check interfaces with many popular Remote Monitoring Units, which can be installed adjacent to the unit for real-time field data.
Note: 10 cm² coupons are preferred, as the measured value converts easily to amperes per square metre (A/m²).
-
Standard Components
The Rapid-Check ships with the following components as standard, which together make installation straightforward.
Qty Component 1 Lexan test station body, 3" diameter 2 Pipeline connection terminals (black) 1 Stationary copper sulfate reference electrode terminal (yellow) 1 Native coupon terminal, isolated from all structures (white) 1 AC/DC coupon terminal (green) with momentary disconnect switch 1 0.1 ohm shunt 1 Printed nameplate 1 “Dead” front panel with pre-wired banana jacks 1 Rear shock-guard safety cover 1 3" x 6' long PE standpipe 1 Quick-Connect terminal strip with cable connection guide 1 Test station schematic drawing Key Specifications
Body Lexan, 3" diameter Standpipe 3" x 6' long polyethylene Terminal Capacity Quick-Connect terminal strip accepts up to #6 AWG cable Shunt 0.1 ohm, wired in line with the AC/DC coupon Terminals 2x pipeline (black), reference electrode (yellow), native coupon (white), AC/DC coupon (green) Switching Momentary disconnect switch on the AC/DC coupon terminal Safety Dead-front panel with pre-wired banana jacks; rear shock-guard cover Wiring Pre-wired at the factory; labelled terminal block with cable connection guide Colour Specified at time of order RMU Interface Compatible with many popular Remote Monitoring Units -
Applications
The Rapid-Check is purposely built to allow specific CP test measurements, including but not limited to the following.
Pipe-to-Soil Potentials
Taken with a portable or stationary reference electrode, to test the effectiveness of the CP system and detect the presence of cathodic interference.
Coupon Measurements
- Native structure-to-soil potential.
- CP “on” potential.
- Coupon disconnect potential, emulating an instant CP-off potential.
- AC current density for pipelines installed in AC power transmission corridors.
Note: induced AC voltages and the associated AC currents can be both a personnel shock hazard and, in some cases, a threat to pipeline integrity from AC corrosion.
-
Ordering Information & Options
When ordering a Rapid-Check test station, please confirm the following.
- Test station colour. Specify the colour required.
- Standard configuration. Confirm that the standard configuration meets the needs of your site.
- Optional equipment. Coupons, a reference electrode, wiring and similar accessories can be supplied alongside the station.
Remote Monitoring
Many CP operators are installing Remote Monitoring Units to obtain real-time field data. The Rapid-Check interfaces with many popular RMU products, and the RMU can be installed adjacent to the Rapid-Check unit.
Contact Farwest Corrosion at (310) 532-9524 or submit a quote request to configure a Rapid-Check for your application.
Documentation
-
Frequently Asked Questions
What readings can the Rapid-Check take?
Pipe-to-soil potentials with a portable or stationary reference electrode, native structure-to-soil potential, CP “on” potential, coupon disconnect potential emulating an instant-off reading, and AC current density.
Does it come pre-wired?
Yes. Every assembly is pre-wired at the factory and fitted with a labelled Quick-Connect terminal block, so the installer attaches each field wire to its specified position and the wiring is complete.
What size cable does the terminal strip accept?
Up to #6 AWG.
How is AC current density measured?
A 0.1 ohm shunt is wired in line with the AC/DC coupon. A direct AC current density reading can also be taken by connecting a digital multimeter to the appropriate terminals. 10 cm² coupons are preferred because the measured value converts easily to A/m².
How does the coupon disconnect reading work?
The AC/DC coupon terminal is electrically connected to the pipeline terminal. A momentary toggle switch disconnects the coupon from the pipeline, giving a coupon disconnect potential that emulates an instant CP-off reading.
Is it safe to work on in the field?
The station uses a dead-front panel with pre-wired banana jacks and a rear shock-guard safety cover to prevent contact with live wires and terminals.
Can it work with a remote monitoring unit?
Yes. The Rapid-Check interfaces with many popular RMU products, and the RMU can be installed adjacent to the unit.
What is included in the standpipe?
A 3" x 6' long polyethylene standpipe is supplied as part of the standard assembly.