Cyclone-10 Cathodic Protection Coupon (10 cm² Cylindrical Steel)
- The Cyclone-10 is a 10 cm² cylindrical “barrel” cathodic protection coupon in a durable PVC housing, a shape long established in CP testing. Supplied with dual #12 AWG stranded copper leads in RHH/RHW direct-burial insulation, in 25, 50, 75 or 100 foot lengths.
-
Cathodic protection coupons are a simple, size-specific piece of metal with one or more wires attached, used to evaluate the corrosion control or cathodic protection system protecting a structure — typically a steel pipeline.
Measurements a Coupon Supports
- Native or unprotected structure-to-soil potentials.
- Structure-to-soil potentials with the CP system energised.
- Structure-to-soil potentials with the CP system interrupted.
- A “coupon interrupt” reading, emulating an “off” structure-to-soil potential without interrupting CP current.
- Magnitude measurements of AC current density on a structure with known induced AC issues.
The Cyclone-10 Design
The Cyclone-10 steel CP coupon is a 10 cm² “barrel” or cylindrical coupon, a form common in CP testing. The coupon is mounted inside a durable PVC housing and is supplied with a dual length of #12 AWG stranded copper cable with RHH/RHW direct-burial insulation, typically green in colour.
Why 10 cm²
A 10 cm² coupon makes better contact with native earth than a 1 cm² coupon, and for AC current density work the measured value converts directly from milliamps to A/m² with no arithmetic. A reading of 25.0 mA is 25 A/m².
The Cyclone-10 shares its 10 cm² area with the hemispherical Hemi-10 and the flush-mounted Flathead-10 — the difference is the geometry presented to the soil.
-
Specifications
Surface Area 10 cm² Shape Cylindrical (“barrel”) Material Steel Housing Durable PVC Cable Dual length of #12 AWG stranded copper Cable Insulation RHH/RHW, rated for direct burial Cable Lengths 25, 50, 75 or 100 feet Insulation Colour Green standard; white, blue, orange and others available Typical Use Coupon interrupt readings and AC current density measurement Conversion 10 cm² converts mA directly to A/m² -
Coupon Ordering Information
To order a Cyclone-10, confirm the following.
- Specify the Cyclone-10 steel coupon.
- Choose a cable length of 25, 50, 75 or 100 feet.
- Select a cable insulation colour. Green is the Farwest standard; white, blue, orange and others are available.
Contact Farwest Corrosion at (310) 532-9524 or submit a quote request.
-
Frequently Asked Questions
What shape is the Cyclone-10?
Cylindrical — a “barrel” profile that is long established in CP testing, with 10 cm² of exposed steel.
How does it compare to the Hemi-10 and Flathead-10?
All three present 10 cm² of steel. The Cyclone-10 is cylindrical, the Hemi-10 hemispherical for maximum earth contact, and the Flathead-10 flush mounted in its housing.
Does it come with one lead or two?
The Cyclone-10 is supplied with a dual length of #12 AWG stranded copper cable, which gives a dedicated measurement path alongside the structure connection.
Why does 10 cm² matter for AC current density?
At 10 cm² the measured milliamp value converts directly to amperes per square metre, so a reading of 25.0 mA is 25 A/m² with no calculation.
What cable lengths are available?
25, 50, 75 or 100 feet, with RHH/RHW insulation rated for direct burial.
Can I get a cable colour other than green?
Yes. Green is the Farwest standard; white, blue, orange and others are available.
What is a coupon interrupt reading?
It emulates an “off” structure-to-soil potential without interrupting CP current to the structure.