Flathead-1 Cathodic Protection Coupon (1 cm² Steel)
- The Flathead-1 is the industry-standard 1 cm² cathodic protection coupon: 1018 alloy steel flush mounted in a durable PVC housing, supplied with single or dual #12 AWG stranded copper test leads in RHH/RHW direct-burial insulation, in 25, 50, 75 or 100 foot lengths.
-
Cathodic protection coupons are a simple, size-specific piece of metal with one or more wires attached, used to evaluate the corrosion control or cathodic protection system protecting a structure — typically a steel pipeline.
Measurements a Coupon Supports
- Native or unprotected structure-to-soil potentials.
- Structure-to-soil potentials with the CP system energised.
- Structure-to-soil potentials with the CP system interrupted.
- A “coupon interrupt” reading, emulating an “off” structure-to-soil potential without interrupting CP current.
- Magnitude measurements of AC current density on a structure with known induced AC issues.
- Use as an isolated coupon to evaluate native or unprotected potentials.
The Flathead-1 Design
The Flathead-1 steel coupon is a 1 cm² coupon made from 1018 alloy steel. The coupon is flush mounted inside a durable PVC housing, which keeps the exposed surface area fixed and repeatable from one reading to the next.
Each coupon includes a specified length of #12 AWG stranded copper cable with RHH/RHW direct-burial insulation, typically green in colour.
Choosing Between 1 cm² and 10 cm²
The Flathead-1 is the long-standing industry standard for routine coupon potential work. Where the job calls for AC current density measurement, a 10 cm² coupon makes better contact with native earth and converts milliamps directly to A/m² without arithmetic — see the Flathead-10, Hemi-10 or Cyclone-10.
-
Specifications
Surface Area 1 cm² Material 1018 alloy steel Mounting Flush mounted in a durable PVC housing Cable #12 AWG stranded copper Cable Insulation RHH/RHW, rated for direct burial Lead Options Single or dual cable lead Cable Lengths 25, 50, 75 or 100 feet Insulation Colour Green standard; white, blue, orange and others available Typical Use Coupon potential and coupon interrupt readings -
Coupon Ordering Information
To order a Flathead-1, confirm the following.
- Specify the Flathead-1 steel coupon.
- Select the number of cable lead wires, 1 or 2.
- Choose a cable length of 25, 50, 75 or 100 feet.
- Select a cable insulation colour. Green is the Farwest standard; white, blue, orange and others are available.
Contact Farwest Corrosion at (310) 532-9524 or submit a quote request.
-
Frequently Asked Questions
What steel is the Flathead-1 made from?
1018 alloy steel, with 1 cm² of surface area exposed.
Why is the coupon flush mounted?
Flush mounting in the PVC housing fixes the exposed surface area, so the area behind every reading stays the same and results are comparable over time.
What is a coupon interrupt reading?
It emulates an “off” structure-to-soil potential without interrupting CP current to the structure, giving an instant-off style reading while the system stays energised.
Should I use a 1 cm² or a 10 cm² coupon?
1 cm² is the established standard for routine coupon potential work. For AC current density, a 10 cm² coupon gives better earth contact and converts mA directly to A/m².
What cable is supplied?
#12 AWG stranded copper with RHH/RHW insulation rated for direct burial, in 25, 50, 75 or 100 foot lengths, as a single or dual lead.
Can I get a cable colour other than green?
Yes. Green is the Farwest standard; white, blue, orange and others are available, which helps where several coupons share one test station.
Can it be used as an isolated coupon?
Yes. Left disconnected from the structure, it evaluates native or unprotected potentials.