Hemi-10 Dual Cathodic Protection Coupon (Two 10 cm² Steel)

The Hemi-10 Dual pairs two 10 cm² hemispherical steel coupons in a single durable PVC housing, shaped for maximum contact with native earth. Supplied with three or four #12 AWG stranded copper leads in RHH/RHW direct-burial insulation, in 25, 50, 75 or 100 foot lengths.
  • Cathodic protection coupons are a simple, size-specific piece of metal with one or more wires attached, used to evaluate the corrosion control or cathodic protection system protecting a structure — typically a steel pipeline.

    Measurements a Coupon Supports

    • Native or unprotected structure-to-soil potentials.
    • Structure-to-soil potentials with the CP system energised.
    • Structure-to-soil potentials with the CP system interrupted.
    • A “coupon interrupt” reading, emulating an “off” structure-to-soil potential without interrupting CP current.
    • Magnitude measurements of AC current density on a structure with known induced AC issues.

    The Hemi-10 Dual Design

    The Hemi-10 Dual steel CP coupon comprises two 10 cm² half-round coupons designed for maximum contact to earth, which is critically important for AC current density measurements.

    The dual 10 cm² arrangement gives excellent contact with native earth compared with smaller 1 cm² coupons. For AC current density work, the 10 cm² surface area also allows a direct conversion from mA to A/m² with no mathematical conversion.

    Both coupons are mounted inside a durable PVC housing, and the assembly is supplied with three or four lengths of #12 AWG stranded copper cable with RHH/RHW direct-burial insulation.

    Why Two Coupons in One Housing

    A dual coupon lets one element stay connected to the structure while the other is held native or used for a separate measurement — both sitting in identical soil conditions at the same depth, so readings are directly comparable in a way two separately buried coupons cannot guarantee.

  • Specifications

    ConfigurationTwo coupons in a single housing
    Surface Area10 cm² each
    ShapeHemispherical (half-round), for maximum contact to native earth
    MaterialSteel
    HousingDurable PVC
    Cable#12 AWG stranded copper
    Cable InsulationRHH/RHW, rated for direct burial
    Lead OptionsThree or four cable leads
    Cable Lengths25, 50, 75 or 100 feet
    Insulation ColourWhite, blue, orange and others available as required
    Conversion10 cm² converts mA directly to A/m²
  • Coupon Ordering Information

    To order a Hemi-10 Dual, confirm the following.

    • Specify the Hemi-10 Dual steel coupon.
    • Select the number of cable lead wires, 3 or 4.
    • Choose a cable length of 25, 50, 75 or 100 feet.
    • Select cable insulation colours as required — white, blue, orange and others are available, which helps identify each lead at the test station.

    Contact Farwest Corrosion at (310) 532-9524 or submit a quote request.

  • Frequently Asked Questions

    What makes this a “dual” coupon?

    Two separate 10 cm² hemispherical steel coupons are mounted in one PVC housing, each with its own lead, so they can be measured independently.

    Why would I want two coupons together?

    Both elements sit in identical soil at the same depth, so one can stay connected to the structure while the other is held native and the two readings remain directly comparable.

    How many leads does it come with?

    Three or four lengths of #12 AWG stranded copper cable, specified at time of order.

    Why does 10 cm² matter for AC current density?

    At 10 cm² the measured milliamp value converts directly to amperes per square metre, so a reading of 25.0 mA is 25 A/m² with no calculation.

    How does it compare to the single Hemi-10?

    Same hemispherical 10 cm² element and housing design; the Dual carries two of them with additional leads.

    What cable lengths are available?

    25, 50, 75 or 100 feet, with RHH/RHW insulation rated for direct burial.

    Can each lead be a different colour?

    Yes. Insulation colours are selected as required, which makes identifying each lead at the test station straightforward.

    Dimensional Drawing

    Hemi-10 Dual cathodic protection coupon drawing
Customers Who Viewed This Also Viewed
External Mount Split Wall Sleeves
Cadweld Plus Electronic Welding Control Unit by Erico
Solar Power Supply for Cathodic Protection by Farwest Corrosion
Model IDC DryConn Yellow Connector by King Innovations
Soil Resistivity Apparatus, Model 54, by Collins